One grower tells you to run your nutrient solution at 1,200 ppm. Another says 1,680. Your own meter says 2.4. Nobody is lying, and your meter is not broken.
All three numbers can describe the same liquid. The meter measures electrical conductivity (EC), and ppm is a number calculated from it, using a factor that differs from meter to meter. Here is how to read EC, convert between scales and keep your meters accurate, so your readings mean something next month as well as today.
What does EC actually measure?
Most fertilizers, except urea, are salts. Dissolved in water, they split into charged particles, and those conduct electricity. The more dissolved salts, the higher the EC.
That makes EC an estimate of the total dissolved salts, not a list of what is in the water. It cannot tell you which nutrients are present or whether they are in balance, so an acceptable EC does not prove complete nutrition. A solution that is too concentrated can also make it harder for roots to take up water.
Why do the ppm numbers disagree?
Think of Fahrenheit and Celsius. The temperature is the same, and the number depends on the scale you chose. A meter that shows ppm takes the EC reading and multiplies it by a fixed factor. Two common factors are 500 and 700, which is how one liquid at 2.4 mS/cm becomes 1,200 ppm on one meter and 1,680 ppm on another. Ppm here is an estimate of total dissolved solids, not a lab result for any single nutrient.
The unit trap is just as common. 1 mS/cm = 1 dS/m = 1,000 µS/cm, so divide a µS/cm reading by 1,000 to get mS/cm. If a chart says to multiply µS/cm by 1,000 to get mS/cm, it has the conversion backwards. The safe habit is to record EC with its unit and note which scale the meter was set to.
What EC should I expect?
It depends on what you are measuring, and the two cases below must not be mixed.
A hydroponic nutrient solution. Each crop has its own range. Published examples in mS/cm are basil 1.0 to 1.6, lettuce 1.2 to 1.8, spinach 1.8 to 2.3, cucumber 1.7 to 2.0, pepper 0.8 to 1.8 and tomato 2.0 to 4.0. They are not split into seedling, vegetative and fruiting targets, and EC varies with the plant's stage, so use the range for your crop rather than one number for every leafy green or fruiting plant, and do not apply it to seedlings automatically. In one trial, pepper and tomato seedlings were fed at 1.3 mS/cm, and the feed was raised to 2.0 to 2.5 mS/cm for mature plants.
The root zone of pots of soilless mix. Here the number depends on how you took the sample. For most established greenhouse plants the normal range is 2.7 to 4.6 mS/cm by PourThru, 0.76 to 1.25 by a 1:2 dilution and 2.1 to 3.5 by saturated media extract. Seedlings and salt-sensitive plants sit lower, at 1.0 to 2.6, 0.26 to 0.75 and 0.76 to 2.0. These general bands apply to extracts from soilless mix only, not to a reservoir, garden soil or a mix that contains field soil, and your crop's own needs still matter.
How do I calibrate and look after my meters?
Follow your meter's instructions and use the standard solution they name, and while you learn your meter, calibrate it at the start of each testing session until you know how much it drifts. Use fresh standard solution each time and throw the used portion away. For pH, calibrate at pH 7, or at pH 4 and 7 for a two-point calibration. EC uses its own conductivity standard; 1.41 mS/cm is a common one. Rinse off the buffer, put the sensor in, dislodge any bubbles and wait for the reading to settle.
Many meters correct for temperature automatically, and EC is conventionally reported at 25°C. That correction does not replace calibration.
Care of the pH probe matters as much. The glass tip stays working only if it stays hydrated, so keep it in storage solution, not plain water, and do not rub or touch the sensing tip. Rinse between samples. Published estimates for a pH probe's life are one to two years and about one to three years, depending heavily on use and care. Replace the probe when it can no longer be calibrated. If you ever clean a probe, use the cleaner its maker prescribes. Some probe cleaners are strong acids or bases, so wear eye protection and follow the cleaner's label. Wash your hands before working with a hydroponic system.
How do I measure feed and root zone?
Test your source water first. Know its pH and EC before you mix anything. A pH or EC pen cannot measure alkalinity, so get that from a lab water test, and check that the test you order includes it. For the mixed feed, mix, let it stabilize and read EC before adjusting pH; pH ranges are in pH: why it decides what roots can reach.
For a pot of soilless mix, choose one method and follow it completely: the 1:2 dilution is the simpler test for an occasional check, and PourThru is best for regular monitoring of the same pots.
- PourThru: water as usual until the mix is fully wet, and let it drain for 30 to 60 minutes. Then pour distilled water evenly over the mix and collect what drains out, aiming for about 50 mL each time. For a 6.5-inch pot, about 100 mL of distilled water gives about 50 mL to test; the amount you need varies with the mix and conditions, so write down what you used. Sampling a dry pot can raise the reading, and collecting much more than 50 mL dilutes the sample and lowers it. Runoff from an ordinary watering does not count as a PourThru sample.
- 1:2 dilution: take the mix from the root zone, never just the top inch or two, and pick out any slow-release fertilizer pellets; then mix one volume of the air-dried mix with two of distilled water, wait 30 minutes, filter it through a coffee filter and test.
- Saturated media extract: this is usually done by a lab, because it needs special skills and laboratory equipment. A root-zone sample is wetted with distilled water until it is saturated, with no water standing on top, and the liquid is then drawn off and tested.
Say your lettuce tank reads 2.4 mS/cm and the example range is 1.2 to 1.8. Before touching anything, recheck the calibration, confirm which scale the meter showed and make sure you sampled a tank that was mixed and had settled. Adjust the solution only if the reading still holds after those checks.
What to do this week
- Check which scale your meter shows. Switch it to EC in mS/cm if you can, and write the unit on every reading.
- Calibrate with fresh standards, following your meter's instructions, and store the pH probe in storage solution.
- Measure your source water's pH and EC, and get its alkalinity from a lab water test.
- Choose one root-zone method for your pots, write down its volumes and keep it the same each time.
- Start a log: date, crop and stage, sample, method, volumes, EC and unit, pH, calibration and any change you made.
Use EC as an estimate of dissolved salts, record it the same way every time, and trust a trend more than a single number.
Sources
- Oklahoma State University Extension, Electrical Conductivity and pH Guide for Hydroponics, HLA-6722, 2017.
- Purdue Extension, pH and Electrical Conductivity Measurements in Soilless Substrates, HO-237-W, 2009.
- UMass Extension, How to Use pH and EC "Pens" to Monitor Greenhouse Crop Nutrition.
- University of Minnesota Extension, Small-scale hydroponics.
- Bluelab technical support, What are the different conductivity scales? What do they mean?.
- Utah State University Extension, Utah Fertilizer Guide, AG 431 (glossary: EC "expressed as dS/m ... at 25 C").
- Hanna Instruments, hosted by UMass, pH meters, EC meters and Maintenance, 2016.
- Oklahoma State University Extension, Choosing and using a pH meter for food products, FAPC-117, 2016.
- University of Missouri Extension, Hydroponic Nutrient Solutions, G6984, 2026.
- UMass Extension, Soil Testing (Pour Thru procedure and media sampling).
- UMass Extension, Soluble Salts and Electrical Conductivity (EC) for Greenhouse Crops.
- UMass Extension, Greenhouse Best Management Practices manual: Soil Testing.
- Virginia Cooperative Extension, System and Crop Comparisons: Nutrients, SPES-466.


Share: